Abstract: At 11:20 a.m. on December 20, 2019, an employee was working for a firm that manufactured cable for communications and energy transmission. She was working as a machine operator, or "spark test" operator. She was working on the take up side of line 3510 at the firm's facility. She was operating a Sterling Davis Electric model PORA spooling machine, with serial number C3390. It ran on 480 volts. She was using it take up the firm's catalog number 3XWR5 XLE 0.327-inch-diameter (about AWG gauge 0) wire, onto spool number 974181408. The spool was 18 in. (0.46 meters) in diameter. It was 26.5 in. (0.67 meters) above the ground. She was standing approximately 6 in. (150 mm) from the spool on the take up side of line 3510. Workers generally stood some 6 to 12 in. (150 to 300 mm) from the cable. The employee was standing her distance from the spool because of her height and ability to reach the wire. She was guiding the cable by hand. Her hand was pulled into the spool. The wire continued to spool at a low rpm, while the employee was wrapped in it three times. She was stuck under the cabling machine, and her arm was amputated. She was hospitalized. The employee stated that her left hand was directly touching the wire. She stated that she had been trained to use her hand on top of the wire to guide it into place. She stated the wire was sticky and that her left hand stuck to the wire. She was unable to move her hand, and it was pulled into the spool. She was working alone at the time of the incident, and no one witnessed it. Employee interviews revealed that this practice of employees using their hands to guide cable onto the automatically turning wheels was common and expected by the employer, even though it exposed them to obvious point of operation hazards. The employee spent herentire shift in an unguarded machine area.

Keywords: Amputated, Amputation, Arm, Cable, Caught By, Caught In, Elderly, Hand, Instantaneous amputation, Machine Guarding, Machine operator, Manual Mat Handling, Mech Mat Handling, Rotating Parts, Trapped, Traumatic Amputation

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1452417.015 64 F Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.