Accident Summary Nr: 123543.015 - Employee's finger is partially amputated by unguarded belt/p

Accident Summary Nr: 123543.015 -- Report ID: 0521700 -- Event Date: 01/21/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1459151.01501/29/2020238310M. & O. Insulation Company

Abstract: At 8:45 a.m. on January 21, Employee #1, a heat/frost insulator, and a coworker were preparing to install new insulation on a building's Niagara cooling unit/air handler unit. Employee #1's left hand came in contact with the belt and pulley, which were not fully guarded and were not locked out. Employee #1 required hospitalization and treatment for a partially amputated index finger.

Keywords: Air Conditioner, Belt, Caught In, Construction, Contact, Finger, Installing, Insulation, Lockout/Tagout, Partial Amputation, Pulley, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1459151.015 24 F Hospitalized injury Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.