Accident Summary Nr: 123480.015 - Employee is struck and killed by falling tree

Accident Summary Nr: 123480.015 -- Report ID: 0950615 -- Event Date: 01/27/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1458603.01501/27/2020561730Clements Tree Service Inc.

Abstract: At 11:00 a.m. on January 27, 2020, a crew of 7 workers were removing eucalyptus trees from a wooden hillside between residential properties for the second day. In the wooden area, there were many snag trees, or thin, dead or dying trees that were more than 20 feet tall and less than 12 inches in diameter. The crew had attached a rope at the top of the tree being removed, which had a base diameter of approximately 30 inches and was 54 feet long. The crew was going to use this rigging system to drop the tree once their supervisor had finished making the back-cut on the tree. Employee #1, who was a groundsman, was standing downhill with three coworkers approximately 64 feet away while facing the tree that was going to be removed. The supervisor began felling the tree while Employee #1 and coworkers were downhill pulling on the rigging system. After the supervisor gave the signal, Employee #1 and the coworkers pulled the tree and it began to fall. However, the branch of a tree obstructed the fall of the tree that was being removed. A snag tree, which was approximately 12 inches in diameter and 64 feet in length, fell downhill in a direction perpendicular to the tree being removed and it struck Employee #1 in the head, approximately 15 feet from the top, and resulted in killing Employee #1. Emergency personnel pronounced Employee #1 dead at the scene.

Keywords: Head, Rigging, Struck By, Tree, Tree Felling

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1458603.015 38 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close