Accident Summary Nr: 123123.015 - Employee is scalped by screw drive

Accident Summary Nr: 123123.015 -- Report ID: 0950611 -- Event Date: 01/07/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1455388.01501/10/2020327212Nikolas Weinstein Studios, Inc.

Abstract: At 6:00 p.m. on January 7, 2020, an employee, a shop manager, was working on an unfinished piece of glass artwork. The employee was working on a specially designed, adjustable table that could lower and rise. Once glass artwork was adjusted on the table, it rolled into a glass-heating kiln. The employee was adjusting a piece of artwork when her hair got caught by the unguarded screw drive on the side of the table. The employee was able pull herself free from the entanglement and then called emergency services. The employee was hospitalized to treat a scalp avulsion.

Keywords: Avulsion, Caught In, Entangled, Hair, Hydraulic Table, Kiln, Scalp, Scalped, Screw Conveyor, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1455388.015 31 F Hospitalized injury Managers and administrators, n.e.c

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close