Accident Summary Nr: 123067.015 - Employee incurs concussion when struck by Marooka buggy boom

Accident Summary Nr: 123067.015 -- Report ID: 0627510 -- Event Date: 01/08/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1454954.01501/09/2020237120Whc Energy Services

Abstract: At 11:00 a.m. on January 8, 2020, an employee was releasing a heating ring. As the employee was lifting the heating ring, the boom of the Marooka buggy bolts sheared, causing the boom to strike the employee. The employee suffered a concussion and was hospitalized.

Keywords: Boom, Concussion, Lifting, Struck By
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition  

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Construction
1 1454954.015 35 M Hospitalized injury Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.