Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 122770.015 - Employee incurs multiple injuries in fall from roof

Accident Summary Nr: 122770.015 -- Report ID: 0950641 -- Event Date: 08/31/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1429608.01509/10/2019238220Salinas Ac Inc.

Abstract: At 1:30 p.m. on August 31, 2019, Employee #1, employed by an air conditioning company, was traversing the roof of a six-story commercial building. The employee fell from the roof and struck the cement walkway at surface level. He was transported to the hospital for treatment of multiple fractures and internal injuries.

Keywords: Air Conditioner, Blunt force trauma, Construction, Fall, Fall Protection, Fracture, Internal Injuries, Roof, Walking Surface, Work Surface

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1429608.015 23 M Hospitalized injury Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close