Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 122761.015 - Employee using shear suffers partial amputation of fingertip

Accident Summary Nr: 122761.015 -- Report ID: 0112000 -- Event Date: 12/10/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1452911.01512/23/2019332999Walker Magnetics

Abstract: At 7:20 a.m. on December 10, 2019, an employee was working as an assembler for a firm that designed and manufactured magnets for scrap metal processing operations. He was working in the firm's fabrication area. He was cutting small pieces of fiberglass insulation board on a Lodge & Shipley model 0408 straight shear. The employee was pushing the material toward the blade, when his finger went under the guard for one of the hold-downs. The shear cycled, and his finger was caught under the hold-down. When he tried to pull his hand free, the tip of his finger was partially amputated. He was treated without hospitalization. The barrier guard on the shear allowed access to both the hold-downs and the point of operation. The guard provided on the first hold-down was raised high enough to allow fingers to pass underneath and into the path of the hold-down. Sight openings provided in the guard were large enough to reach through to the shear point. In at least one area, vertical members in the guard were bent, creating a space that could be reached through to the shear point.

Keywords: Amputated, Amputation, Assembling, Caught In, Cutting, Electric Magnet, Fiberglass, Finger, Fingertip, Hand, Instantaneous amputation, Machine Cycled, Machine Guarding, Magnet, Metal Shop, Partial Amputation, Shear, Traumatic Amputation

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1452911.015 43 M Non Hospitalized injury Assemblers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.