Accident Summary Nr: 122315.015 - Employee fractures hips in fall from ladder

Accident Summary Nr: 122315.015 -- Report ID: 0522300 -- Event Date: 12/02/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1449658.01512/06/2019532412Sunbelt Rentals Inc.

Abstract: At 9:30 a.m. on December 2, 2019, Employee #1, a 50-year old male, fell from a 10-foot fiberglass ladder while attempting to repair/troubleshoot a 14-foot mechanical garage door. Employee #1 attempted to raise and lower the door via the mechanical controls. Coworkers stated that they were able to hear the mechanical gears moving, but the door was not functioning. At that point, the coworkers attempted to utilize the manual controls (a rope chain that manually winds the internal controls of the garage door opener to raise and lower the door) to raise and lower the door. This manual process released the tension, which was supporting the raised garage door. Then Employee #1 placed a 10-foot fiberglass step ladder directly under the overhead door and began to diagnose the problem. Employee #1 found that the base of the garage door (bowed inward) was stuck on the lip of the cross beam and utilized a 3-foot piece of steel rebar to pry the door free. As Employee #1 released/pried the bottom of the door off the ledge of the cross beam/catch point, the stored energy forced the garage door to rapidly close, striking Employee #1 and the ladder, causing the employee to fall from the ladder. The coworkers stated that they did not attempt to lockout/tagout the energy source prior to attempting to fix the issue. The coworkers also stated that Employee #1 was on the ladder, a coworker was holding the base of the ladder, and an additional coworker and the foreman were approximately 15 feet inside the bay assisting/watching and providing verbal assistance during this process. The manager called 911, EMS arrived and transported the employee for treatment for fractured hips. The employee was hospitalized.

Keywords: Chain, Door, Fall, Fall From Elevation, Falling Object, Fracture, Hip, Ladder, Lockout/Tagout, Overhead Door, Rebar, Repair, Troubleshooting

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1449658.015 50 M Hospitalized injury Heating, air conditioning, and refrig. mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close