Accident Summary Nr: 122003.015 - Employee fractures vertebrae in fall from slippery roof

Accident Summary Nr: 122003.015 -- Report ID: 0524200 -- Event Date: 11/20/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1447508.01511/26/2019238160Tidwell Construction Ltd. Dba Tidwell Roofing & Sheet Metal

Abstract: At 9:00 a.m. on November 20, 2019, an employee working as a roofer for a roofing and sheet metal contractor was accessing a roof to determine where to install fall protection anchorage points. The employee accessed the roof carrying a leaf blower to remove ice and water from the roof on his way to the peak of the roof. The employee began walking towards the peak when he slipped and fell to the ground. The employee fractured his vertebrae and sustained contusions to his back, requiring hospitalization.

Keywords: Anchor, Back, Blunt force, Blunt force trauma, Clearing, Commercial Building, Construction, Contusion, Fall, Fall From Elevation, Fall Protection, Fracture, Installing, Roof, Roofer, Slip, Slippery Surface, Vertebra, Walking Surface, Water, Weather, Wet
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Contractor's yard/facility Maintenance or repair   1 13

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1447508.015 42 M Hospitalized injury Roofers Distance of Fall: 13 feet
Worker Height Above Ground/Floor: 13 feet
Cause: Roofing
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.