Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 121756.015 - Employee is killed when struck by falling tree

Accident Summary Nr: 121756.015 -- Report ID: 0316400 -- Event Date: 07/02/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1445337.01507/02/2019113310Michael Warner Logging

Abstract: At 9:32 a.m. on July 2, 2019, Employee #1 was felling a tree using a chainsaw. The tree fell on the employee, crushing his chest and killing him.

Keywords: Chain Saw, Chest, Falling Object, Struck By, Tree, Tree Felling

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1445337.015 73 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close