Accident Summary Nr: 121403.015 - Employee sustains multiple fractures when struck by falling

Accident Summary Nr: 121403.015 -- Report ID: 0419700 -- Event Date: 10/25/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1442812.01511/05/2019532490Avl Productions Inc.

Abstract: At 11:00 a.m. on October 25, 2019, an employee working for an industrial equipment rental company was rigging a point for a sound system. The wind blow and outrigger of the lift were not set up and the lift fell striking the employee. The employee sustained a heel fracture, elbow dislocation, rib fracture and L2-L3 fractures, requiring hospitalization.

Keywords: Aerial Lift, Aerial Lift Controls, Aerial Truck, Back, Chest, Dislocated, Elbow, Falling Object, Foot, Fracture, Industrial Truck, Misjudgment, Misjudgment of Hazardous Situation, Powered Industrial Vehicle, Rib, Spine, Struck By, Vertebra, Work Surface

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1442812.015 33 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.