Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 120325.015 - Employee fractures back in fall from dump trailer to ground

Accident Summary Nr: 120325.015 -- Report ID: 0950624 -- Event Date: 04/03/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1396639.01504/29/2019111333Planasa, Llc

Abstract: At 1:30 p.m. on April 3, 2019, an employee was standing on top of compost material in a Lufkin dump trailer using a shovel to move material from the edge into the bed of the trailer. the employee slipped off the edge and fell approximately 8 feet the ground. The employee fractured his lumbar vertebra and required hospitalization.

Keywords: Agriculture, Agriculture Machinery/Vehicle, Back, Blunt force, Blunt force trauma, Delivery Work, Driver, Fall, Fall Protection, Farm Machinery, Fracture, Material Handling, Motor Vehicle, Shovel, Trailer, Truck Driver, Vertebra

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1396639.015 53 M Hospitalized injury Truck Driver: Heavy/Tractor-Trailer

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close