Accident Summary Nr: 120276969 - Employee dies in trench cave-in

Accident Summary Nr: 120276969 -- Report ID: 0950632 -- Event Date: 01/11/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
12027696901/11/200017940Jsa Engineering Inc

Abstract: On January 11, 2000, Employee #1 was working in an excavation that was approximately 8 ft in depth that was not adequately slopped or shored to protect from a cave-in. He was doing hand shovel work preparing the site for removal of an old water line and replacement with a new one. Employee #1 had been working in the excavation for approximately 10 to 15 minutes when it caved-in. Employee #1 died.

Keywords: ASPHYXIATED, TRENCH, TRENCH DIGGER, CRUSHED, BURIED, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline Alteration or rehabilitation $500,000 to $1,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 120276969 Fatality Asphyxia Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.