Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 119958.015 - Employee incurs burns during malfunction when TCU explodes

Accident Summary Nr: 119958.015 -- Report ID: 0418200 -- Event Date: 09/13/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1431826.01509/16/2019325520D.H.M. Adhesives, Inc.

Abstract: At 1:00 a.m. on September 19, 2019, an employee was inspecting equipment that had malfunctioned trying to determine the cause when the temperature control unit (TCU) exploded. The employee sustained 1st, 2nd and 3rd degree burns to his face, arms and legs and was hospitalized.

Keywords: Adhesive, Arm, Burn, Equipment Operator, Explosion, Face, Fire, High Temperature, Leg, Lung, Malfunction, Mech Malfunction, Skin, Struck By, Temperature

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1431826.015 56 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.