Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 119732.015 - Employee is injured when crane tips over

Accident Summary Nr: 119732.015 -- Report ID: 0854910 -- Event Date: 06/25/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1411459.01506/25/2019324110Marathon Petroleum Company, Lp

Abstract: At 11:38 a.m. on June 25, 2019, an employee was preparing to lift scaffolding to the top of a storage tank with a crane. The crane tipped over, causing the employee to fall out of the crane's cab onto various pipes. The employee sustained unspecified injuries. The employee was taken to the hospital and was admitted for treatment of the injuries sustained.

Keywords: Concussion, Crane, Crane Cab, Crane Operator, Fall, Fall From Elevation, Head, Operating, Operator, Pipe, Refinery, Scaffolding, Storage Tank

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1411459.015 55 M Hospitalized injury Crane Operator

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close