Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 119052.015 - Employee incurs injuries in fall through skylight

Accident Summary Nr: 119052.015 -- Report ID: 0636900 -- Event Date: 08/15/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1424241.01508/19/2019811412Kahn Mechanical Contractors

Abstract: At approximately 2:15 p.m. on August 15, 2019, an employee was walking backward laying out an extension cord. The employee fell through a skylight and sustained internal injuries. The employee was hospitalized for these injuries.

Keywords: Cord Set, Fall, Fall From Elevation, Skylight, Walking Backward

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1424241.015 30 M Hospitalized injury Plumbers, Pipefitters, & Steamfitters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close