Accident Summary Nr: 118888.015 - Employee's arm is fractured when struck by falling pipe

Accident Summary Nr: 118888.015 -- Report ID: 0950612 -- Event Date: 08/06/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1422674.01508/12/2019238190Paragon Mechanical Inc.

Abstract: At 12:15 p.m. on August 6, 2019, Employee #1 and two coworkers, employed by an HVAC company, were loading copper steel pipes onto a truck bed outside the employer's warehouse/shop area. They were using a forklift and an 8-foot sling strap to load a 26-foot, 494-pound pipe when the strap slipped off the fork, causing the pipe to fall and crush Employee #1's arm. Employee #1 was transported and admitted to the hospital for treatment of a fractured arm.

Keywords: Arm, Construction, Crushed, Falling Object, Forklift, Fracture, HVAC, Hoist, Load Shift, Metal Pipe, Rigging, Sling, Struck By, Truck

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1422674.015 63 M Hospitalized injury Truck Driver: Heavy/Tractor-Trailer

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.