Accident Summary Nr: 118468.015 - Employee suffers broken fibula and tibia from automatic can

Accident Summary Nr: 118468.015 -- Report ID: 0521100 -- Event Date: 07/25/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1419467.01507/31/2019311421Del Monte Foods, Inc.

Abstract: At 2:00 a.m. on July 25, 2019, an employee was operating Line 3 Whallon Can Palletizer. The employee was the machine operator for the Line 3 pallet stacker (Whallon/Brite Stacker). The machine was operated in automatic mode wherein a magnetic head raised cans from a table fed by a conveyor and swung 90 degrees towards the operator's platform and placed the cans on top of a pallet. The employee observed the operation of the machine, placed cardboard sheets between the layers of cans, and attempted to ensure that cans did not fall off the pallet stack. There was a pressure mat positioned at the corner of the operator platform that was not secured in place. At the time of the incident, the pressure mat only stopped the movement of the magnetic head when the magnet was raising up from the table, swinging towards the operator platform, and/or lowering the cans onto the pallet. The employee went to retrieve a can(s) that had fallen off the pallet or had lost his balance and fell in between the base of the magnet head and the fixed pallet conveyor frame. The employee's right leg was pinched between the base plate and the fixed frame. The employee suffered breaks to the right fibula and tibia as a result of the incident. The employee was hospitalized for treatment.

Keywords: Automatic Machine, Broken Bone, Caught Between, Conveyor, Fall, Food processing, Leg, Lost Balance, Machine operator, Magnet, Pallet, Palletized Cargo, Pinched, Platform, Tibia

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1419467.015 55 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close