Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 118288.015 - Employee breaks foot when struck by lumber after PIV brake f

Accident Summary Nr: 118288.015 -- Report ID: 0355111 -- Event Date: 05/28/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1405610.01506/05/2019321920Murdock Acquisition Llc

Abstract: At 11:00 a.m. on May 28, 2019, an employee was utlilizing a forklift powered industrial vehicle (PIV) pulling orders when the PIV parking brake failed. The PIV rolled into lumber and the employee was struck by the lumber. The employee broke his right foot, requiring medical treatment. The employee was not hospitalized.

Keywords: Blunt force, Blunt force trauma, Brake, Caught Between, Collision, Crushed, Equipment Operator, Foot, Forklift, Fracture, Inadequate Maint, Industrial Truck, Loading, Lumber, Lumber Stack, Malfunction, Material Handling, Powered Industrial Vehicle, Struck Against, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1405610.015 28 M Non Hospitalized injury Equipment Operator: Heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close