Accident Summary Nr: 117641.015 - Employee amputates finger between conveyor roller and bar

Accident Summary Nr: 117641.015 -- Report ID: 0524700 -- Event Date: 06/24/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1412862.01507/02/2019332111Carbo Forge, Inc.

Abstract: At 9:00 a.m. on June 24, 2019, an employee was operating an Advanced Machine Design Company, Model #530-2230, 530 Ton Hydraulic Shear to cut steel bars. The employee pushed a bar into the shear with his left hand and as the bar contacted the probe it pushed the bar back to be cut to the desired length. When the bar got pushed back, it pinched the employee's index finger between the bar and the rollers of the auxiliary conveyor. The employee sustained a crushing injury of the left index finger resulting in a partial amputation of the finger at the first knuckle and requiring medical treatment.

Keywords: Amputated, Amputation, Caught Between, Conveyor, Crushed, Cutting, Finger, Fingertip, Hand, Hydraulic Press, Lockout/Tagout, Machine Guarding, Metal Bar, Partial Amputation, Pinched, Power Press, Press, Press Operator, Roller Conveyor, Shear, Sheared, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1412862.015 22 M Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.