Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 116865.015 - Employees are burned in flash fire while breaking piping

Accident Summary Nr: 116865.015 -- Report ID: 0830500 -- Event Date: 06/05/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1405972.01506/05/2019332710Femco Holdings, Llc

Abstract: At 9:00 a.m. on June 5, 2019, an Employee #1, Employee #2 and Employee #3 were breaking piping with electric impact tools when a flash fire broke out burning the employees on their back, face, and hands. All three employees were hospitalized with burns to multiple body parts.

Keywords: Back, Burn, Chemical Vapor, Face, Fire, Flammable Vapors, Hand, Hand Tool, Pipe, Pipe Wrench, Smoke
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline Alteration or rehabilitation   1 6

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1405972.015 43 M Hospitalized injury Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:
2 1405972.015 24 M Hospitalized injury Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:
3 1405972.015 20 M Hospitalized injury Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close