1373748.01501/25/2019337110Pacific Coast Cabinets

Abstract: At 9:03 a.m. on January 9, 2019, an employee was ripping a piece of wood with a Powermatic Model No. 66 Table Saw with no guard in place. The employee was caught by the rotating blade and pulled close to the point of operation. The employee amputated his left ring and index fingers and required medical treatment. The employee was not hospitalized.

Keywords: Amputated, Amputation, Blade, Caught By, Cutting, Equipment Operator, Finger, Guard, Hand, Injury Illness Prevention Program, Machine Guarding, Machine operator, Point Of Operation, Push Stick, Rip, Rotating Parts, Saw, Table Saw, Unguarded, Wood Board

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1373748.015 42 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.