Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 115919.015 - Employee is burned by hydrochloric acid

Accident Summary Nr: 115919.015 -- Report ID: 0552652 -- Event Date: 12/26/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1386525.01505/03/2019332812National Galvanizing Lp

Abstract: At 9:00 a.m. on December 26, 2018, an employee was transferring hydrochloric acid from a holding tank to the company's storage tank. After the liquid was transferred into the storage tank, the employee went down into the pit to disconnect the hydrochloric acid hose. As he started loosening the flanges, the quick disconnect broke off releasing hydrochloric acid directly onto the employee. Employee was wearing safety glasses and a hard hat. He sustained second degree chemical burns on his torso from the chest down.

Keywords: Accidental Discharge, Burn, Chemical Burn, Chemical Exposure, Disconnecting Means, Hydrochloric Acid, PPE, Storage Tank, Torso

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1386525.015 50 M Hospitalized injury Electricians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.