Accident Summary Nr: 115630.015 - Employee's hands, arms, and face are burned in flammable vap

Accident Summary Nr: 115630.015 -- Report ID: 0552652 -- Event Date: 03/15/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1391287.01504/23/2019562991A Restroom Trailer Co

Abstract: At 3:30 p.m. on March 15, 2019, Employee #1, employed by a trailer manufacturing company, was using an electric Sawzall to cut his way out of a restroom trailer. He had just finished applying a flammable adhesive to the wallboard in the trailer. There was not adequate ventilation for the flammable adhesive vapors in the trailer so an explosion occurred during cutting. Employee #1 received burns to his hands, arms, and face from the flash explosion. He was hospitalized.

Keywords: Arm, Burn, Cutting And Burning, Electric Saw, Explosion, Face, Fire, Flammable Vapors, Hand, Trailer

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1391287.015 39 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.