Accident Summary Nr: 115152.015 - Employee is struck by tool and falls from ladder; later dies

Accident Summary Nr: 115152.015 -- Report ID: 0521700 -- Event Date: 04/05/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1391155.01504/05/20198113101 Heavy Equipment Loading Inc.

Abstract: At 9:15 a.m. on April 5, 2019, an employee was working from a five-foot ladder and was disconnecting a hydraulic fluid line from the top of a brake accumulator during the dismantling of a Caterpillar 980G Wheel Loader. The employee was struck in the head by a tool he was using or by the hydraulic line fitting and fell to the concrete floor. The employee was brought to the hospital, where he later died.

Keywords: Automotive Repair, Concrete Slab, Face, Fall, Head, Ladder

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1391155.015 50 M Fatality Mechanical engineering technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.