Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 114966.015 - Employee's toes are crushed by falling steel bars and are la

Accident Summary Nr: 114966.015 -- Report ID: 0552652 -- Event Date: 03/05/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1387409.01504/02/2019331221Bar Processing Corporation

Abstract: At 7:30 p.m. on March 5, 2019, an employee was moving and weighing bundles of steel bars. The lifting sling was not hooked completely on the crane hook and when the employee picked up two bundles of steel, the sling came off the hook. One bundle of steel bars lunged towards the employee and fell on his foot, crushing his right big, second, and third toes. He was hospitalized. Two weeks after the accident, the employee's second and third toe were removed.

Keywords: Amputated, Amputation, Crane, Crushed, Falling Object, Sling, Steel Block, Toe

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1387409.015 27 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.