Accident Summary Nr: 114475.015 - Employee cleaning concrete hopper amputates hand

Accident Summary Nr: 114475.015 -- Report ID: 0950641 -- Event Date: 09/15/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1350514.01510/02/2018238110Kg Mullen Inc

Abstract: At 2:20 p.m. on September 15, 2018, Employee #1, employed by a concrete construction company, was working with a Transcrete P80 Concrete Pump to pour concrete for 16-inch by 16-inch by 12-foot tall columns. Needing to clean out the hopper, he removed the grill and started chipping away at the concrete mix with a hammer. An S-tube activated and pinned his left hand against the inner wall of the hopper. Employee #1's entire left hand was amputated. The employee was transported by emergency services to the hospital, where he was admitted for treatment of the hand amputation.

Keywords: Amputated, Caught Between, Caught In, Cleaning, Concrete, Concrete Pump, Construction, Crushed, Hand, Hopper, Lockout/Tagout, Pinned, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1350514.015 37 M Hospitalized injury Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close