Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 114204.015 - Employee incurs hand and arm injuries when caught by conveyo

Accident Summary Nr: 114204.015 -- Report ID: 0950613 -- Event Date: 10/22/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1355807.01510/25/2018333922Vanderlande Industries, Inc.

Abstract: At 9:15 p.m. on September 22, 2018, an employee was trouble shooting noise coming from baggage conveyor equipment. The employee was standing on an 8 foot extension ladder underneath the moving conveyor belt about 12 feet above the floor. The employee was holding a beam with both hands which was a few inches away when his left hand was caught by one of the rollers which pulled his hand in resulting in compound fractures of the radius & ulna on his left wrist and arm, skin damage on top of his left hand, and ligament/tendon/nerve damage on the left hand.

Keywords: Arm, Baggage Conveyor, Caught By, Conveyor Belt, Extension Ladder, Fracture, Hand, Laceration, Nerve damage, Roller--Mach/Part, Tendon, Wrist

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1355807.015 36 M Hospitalized injury Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.