Accident Summary Nr: 114153.015 - Employee amputates finger in printing press machine

Accident Summary Nr: 114153.015 -- Report ID: 0626300 -- Event Date: 02/28/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1382968.01503/06/2019326112Indevco Plastics, Llc

Abstract: At 11:00 p.m. on February 28, 2019, Employee #1 was setting up a press machine for a new run. The employee changed the direction of the anilox roller without shutting down the machine. The roller was operating in a reverse position than it needed to after set up of the new batch. The employee reached around/through anti-lock doors on the machine and removed the cover from the roller to push the button to reverse its operation and got his finger caught in the machine. The employee amputated the left middle finger to the middle joint. The employee was hospitalized.

Keywords: Caught In, Crushed, Finger, Lockout/Tagout, Machine Guarding, Roller--Const Equip

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1382968.015 35 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close