Accident Summary Nr: 113632.015 - Employee's left hand is crushed in snow plow lift

Accident Summary Nr: 113632.015 -- Report ID: 0551701 -- Event Date: 01/15/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1378707.01502/14/2019921190Village Of Palatine - Public Works

Abstract: At 2:15 p.m. on January 15, 2019, an employee was working for a municipality. He and a coworker were replacing the hydraulic lift cylinder on truck number T-411. The hydraulic cylinder actuated the wing snowplow with which the truck was equipped. The employee was instructing the coworker on what controls to move to assist him. As the employee was trying to get the upper end of the cylinder ram connected to the lift plate, the coworker moved the leveler inside the vehicle to lift the ram. The ram extended much faster than expected, pushing the left plate up and trapping the employee's left hand between the wing plow plate and the lift frame. His hand was cut open and down to the tendons across the back side about 13 millimeters (0.5 inches) wide and below the knuckles to the palm side of the hand. He was hospitalized.

Keywords: Caught Between, Crushed, Hand, Hydraulic Cylinder, Hydraulic Lift, Hydraulic Ram, Laceration, Maintenance, Snowplow Blade, Tendon

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1378707.015 54 M Hospitalized injury Automobile mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close