Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 113612.015 - Employee dumping trash at landfill is struck by falling log

Accident Summary Nr: 113612.015 -- Report ID: 0950633 -- Event Date: 01/22/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1377973.01502/12/2019562212Best Way Disposal Co., Inc.

Abstract: At 11:00 a.m. on January 22, 2019, an employee and his coworker were working at a solid waste landfill in Victorville, CA. It was a permanent site. The employee worked as a transfer driver. He delivered refuse to the dump or landfill. He was operating a "big rig" truck and tractor trailer number 704 to dump trash at the landfill. The employee and his coworker were fulltime employees of the employer. The employee had parked his big rig. He was standing behind the rear door to the trailer and unlatching it so that he could open it and dump the trash. His coworker had parked next to the employee in a separate truck. As the coworker was about to get out of his truck, he saw a large piece of wood or trash fall out of top of the truck the employee was driving and strike the employee. It was a wooden log was about 2 meters (77 inches, or 6.5 feet) long and 0.77 meters (29 or 29.5 inches) in diameter. The truck's load had not been secured from dangerous displacement. The employee suffered fractures to his right ankle, both knees, ribs, head, back, vertebrae. He also suffered torn ligaments. He was airlifted to Loma Linda Medical Hospital. DOSH learned about the incident by telephone call from employer on January 25, 2019. The employer did not comply with reporting requirements; the report was late. DOSH arrived at the site at 11:00 a.m. on February 12, 2019. The employer was cited for a violation of T8 CCR3704: Securing Loads. It was determined that prior to and during the course of the investigation, including, but not limited to February 12, 2019, the employer failed to secure the load from dangerous displacement. As a result, on January 22, 2019 a transport driver was seriously injured when he was struck in the head by a dislodged wooden log measuring 77 inches by 29.5 inches when he attempted to open the trailer door on trailer #704 at the Victorville landfill. The stump was also described as an 8-foot tree stump.

Keywords: Ankle, Back, Emergency Response, Falling Object, Fracture, Head, Knee, Landfill, Log, Rib, Struck By, Tractor Trailer, Truck, Truck Driver, Unsecured, Unstable Load, Vertebra, Waste Proc Fac

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1377973.015 48 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close