Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 113475.015 - Employee fractures leg while off loading equipment from flat

Accident Summary Nr: 113475.015 -- Report ID: 1054113 -- Event Date: 09/25/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1372224.01510/04/20181622237990317722075 - Pacific Northwest Excavating Llc

Abstract: On September 25, 2018, an employee was unloading an excavator from a flatbed trailer and fractured his left leg when struck by the release lever once the chain tension was released. The employee was hospitalized.

Keywords: Chain, Excavator, Fracture, Leg, Struck By, Trailer
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1372224.015 35 M Hospitalized injury Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close