Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 112922.015 - Employee amputates thumb while assisting in centrifuge maint

Accident Summary Nr: 112922.015 -- Report ID: 0950615 -- Event Date: 01/15/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1372876.01501/18/2019562211Clean Harbors Environmental Services Inc.

Abstract: At 1:10 p.m. on January 15, 2019, Employee #1 was assigned to assist the maintenance crew servicing a 4,500 lb centrifuges. Employee #1 was shadowing coworker #1 and coworker #2. They explained to Employee #1 that they do centrifuge maintenance after lunch and asked Employee #1 to assist with servicing the coffin on skid # MPS4416 placing rubber plates on pins to place on skid under the 4,500 lb centrifuge coffin. Employee #1 had safety glasses and gloves only, no tools just his hands to place and hold the pads in place on pins. Coworker #2 lost sight of Employee #1 while lowering the coffin with a Toyota forklift Model Number EJ8N75. Coworker #2 and Employee #1 were assigned to make sure the plate was on the pin and was properly aligned. Employee # 1 had his hand under the load making sure the pad was indeed aligned on the pin. During this process, the coffin became stuck as it was being lowered from fork lift with attachment and slings. Coworker #2 maneuvered the fork lift trying to get the coffin in place and it just fell and crushed and amputated most of Employee #1's thumb nail and bone. The employee was hospitalized.

Keywords: Amputated, Amputation, Crushed, Falling Object, Finger, Forklift, Hand, Powered Industrial Vehicle, Sling, Stuck, Thumb

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1372876.015 34 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close