Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 112764.015 - Employee suffers degloving of hand when caught in nip point

Accident Summary Nr: 112764.015 -- Report ID: 0316700 -- Event Date: 01/10/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1372460.01501/16/2019323111York Wallcoverings, Incorporated

Abstract: At 7:15 p.m. on January 10, 2019, Employee # 1 was trying to line a piece of tape on a moving roller. He got his right hand caught in an in going nip point and suffered the degloving of the entire right hand, including tendons. He was hospitalized.

Keywords: Caught In, Degloving, Hand, Nip Point, Roller--Mach/Part, Tendon

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1372460.015 38 M Hospitalized injury Machinists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.