Accident Summary Nr: 112046.015 - One employee is shocked by halogen light, other employee lat

Accident Summary Nr: 112046.015 -- Report ID: 0521400 -- Event Date: 12/21/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1367898.01512/21/2018332811Hudapack Metal Treating Of Illinois, Inc.

Abstract: At 5:30 a.m. on December 12, 2018, Employee #1 had entered the vat and was attempting to reposition a Halogen work light. As he grasped the light with both hands, Employee #1 screamed "Take the light off me". Employee #2 attempted to separate the light and was electrically shocked. Employee #2 then attempted to separate the work light from the flexible power cord that was connected to the lamp cord and was shocked. Employee #2 called for help and contacted the shift supervisor. Other employees responded to the call for help and removed Employee #1 from the vat/tank. CPR was started and 911 was contacted. Employees #1 and #2 were transported to a local hospital for treatment. Employee #1 was pronounced dead at 6:10 at the hospital.

Keywords: CPR, Cord Connector, Electric Shock, Electrocuted, Lighting Fixture, Plug Adapter

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1367898.015 27 M Hospitalized injury Laborers, except construction
2 1367898.015 43 M Fatality Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close