Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 111652.015 - Employee's finger, caught in belt and pulley, is amputated

Accident Summary Nr: 111652.015 -- Report ID: 0950633 -- Event Date: 07/06/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1329168.01507/11/2018237130Calwest Underground, Inc

Abstract: At 9:41 a.m. on July 6, 2018, Employee #1 and a coworker, employed by an underground construction company, were cleaning and attempting to unclog the water lines of a pressure washer, Hydrotek SC 30005D, Max. 3000 PSI, 4.3 GPM, Nozzle -4.5, 14 HP Diesel Kubota Engine. Employee #1 cleared the lines by running compressed air through them. He then turned the washer's motor on. As he attempted to reinstall the hose, the hose slipped. Employee #1's left ring finger became caught in the belt and pulley. The ring finger was amputated, and the middle finger was lacerated. Employee #1 was transported to the hospital, where he received treatment for the amputation and laceration injuries. He was released without hospitalization.

Keywords: Amputation, Belt, Caught In, Cleaning, Construction, Electric Motor, Finger, Laceration, Lockout/Tagout, Pulley, Washing Machine, Water Hose

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1329168.015 56 M Non Hospitalized injury Mechanical controls and valve repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.