Accident Summary Nr: 109438.015 - Employee falls through light panel and is killed

Accident Summary Nr: 109438.015 -- Report ID: 0950625 -- Event Date: 09/24/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1348698.01509/25/2018112120Milky Way Farms

Abstract: At 4:30 p.m. on September 24, 2018, Employee #1 was standing on the peak of the sheet metal roof of the north protective cattle structure. He was removing screws from sheet metal and light panels while Coworker #1 and Coworker #2 were working from a scissor lift below. While standing on the two purlins that run the length of the structure, Employee #1 fell through one of the light panels to the cement ground below, approximately 24 feet, and was killed.

Keywords: Fall, Roof, Roof Opening, Skylight
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building Maintenance or repair   1 24 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1348698.015 30 M Fatality Laborers, except construction Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Roofing
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.