Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 107952.015 - Employee fractures ribs and arm in fall through collapsing r

Accident Summary Nr: 107952.015 -- Report ID: 0419400 -- Event Date: 07/31/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1335613.01508/02/2018238120Mississippi Welding And Machine Llc

Abstract: At 1115 a.m., on July 31, 2018, an employee was working in an aerial lift to remove screws from metal roof components as part of a demolition project. For an unspecified reason, the employee left the basket of the aerial lift and stood upon the metal roof in a section that was previously identified as unsafe due to deteriorating support purlins. When the employee stepped onto the roof, the purlins gave way and he fell eleven feet into a concrete drainage ditch. The employee was hospitalized for fractured ribs and right arm.

Keywords: Aerial Lift, Arm, Basket, Demolition, Fall, Fall Protection, Fracture, Rib, Roof, Roof Collapse
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant Demolition   1 11

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1335613.015 41 M Hospitalized injury Strctural Iron /& Steel Worker Distance of Fall: 11 feet
Worker Height Above Ground/Floor: 11 feet
Cause: Demolition
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.