Accident Summary Nr: 106103.015 - Highway workers struck and killed in work zone

Accident Summary Nr: 106103.015 -- Report ID: 0950631 -- Event Date: 05/31/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1319842.01506/01/2018236210Ccl Contracting, Inc

Abstract: At 8:48 p.m. on May 31, 2018, two employees were working for a contracting firm. The employees were working for a firm that constructed industrial buildings and other projects. Employees #1 and #2 were working at on a night road construction project. The work consisted of excavation and pipe installation in three roadways for a project being conducted for the Water District. The two employees superintendent was in a trailer at the project site. Employees #1 and #2 left the trailer yard at the project site to set up traffic control prior to the overnight work. They left the yard at approximately 8:40 p.m. and traveled westbound to their stopping point. They stopped in the road's bike lane approximately 0.40 km (0.25 miles) east of an intersection. They were in the firm's Chevrolet Silverado. They were towing an arrow board for traffic control. In accordance with engineered traffic plans, and to be in compliance with 8CCR 1598 and the CA Manual on Uniform Traffic Control Devices, four signs had been placed in the bike lane and right shoulder every 152 meters (500 feet) behind the incident location. In order of approach, the signs stated: 1. Road Work Ahead; 2. Right Lane Closed; 3. 40 MPH [or 64 kph, down from a regular speed of 89 kph (55 mph)]; and 4. Merge. The arrow board was the fifth form of traffic control in the sequence encountered by a driver traveling westbound on the road. The vehicle was fully within the bike lane. Employees #1 and #2 exited the vehicle to unhitch the arrow board from the vehicle. The arrow board was also fully within the bike lane. The employees had to unhitch the arrow board. Employee #1 was located between the back of the vehicle and the arrow board on the driver side of the Silverado. Employee #2 was near the rear of the vehicle on the passenger side. At approximately 8:50 p.m., Employees #1 and 2 were struck by a private vehicle. They sustained fatal injuries. They died at the scene of blunt trauma to multiple body parts. They were declared dead onsite and transported to the Orange County Coroner's Office. The Orange County Police Department estimated that the vehicle was traveling at approximately 97 kph (60 mph) when the employees were struck.

Keywords: Alcohol, Automobile, Construction, Flagger, Flagman, Highway, Struck By, Traffic Accident, Traffic Control
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline Maintenance or repair   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1319842.015 35 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Traffic protection
Fatality Cause:
2 1319842.015 50 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Traffic protection
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.