Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 105853.015 - Employee catches hand in die press cutting area and amputate

Accident Summary Nr: 105853.015 -- Report ID: 0522300 -- Event Date: 04/17/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1310674.01504/17/2018326150Aqua Lily Products, Llc

Abstract: On April 17, 2018, an employee was operating the horizontal die press to cut foam pieces. The employee used the manual switch on the bottom right panel on the operator side to cycle the press and had his hand in the hazardous area during the press cycle. The employee caught his hand in the closing action between the ram and cutting blade die, and amputated two fingertips from his right hand. The employee was hospitalized.

Keywords: Amputated, Amputation, Caught By, Die Cutting Press, Finger

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1310674.015 24 F Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close