Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 105148.015 - Employee is struck by flatbed trailer as it falls from jack

Accident Summary Nr: 105148.015 -- Report ID: 1054113 -- Event Date: 03/26/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1308005.01503/28/20187623811310317720100 - Rpd Services Llc

Abstract: At 1:00 p.m. on March 6, 2018, a mechanic and coworker were performing a brake job on a flatbed trailer and had jacked the trailer up. The employee was struck by the trailer when the jack, twisted and fell. The employee fractured his leg and was hospitalized.

Keywords: Automotive Repair, Falling Object, Fracture, Jack, Leg, Trailer

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1308005.015 21 M Hospitalized injury Hand packers and packagers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.