Accident Report Detail
Accident Summary Nr: 105072.015 - Employee sustains injuries from an explosion on a catwalk
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1310708.015 | 04/23/2018 | 324121 | U.S. Polyco |
Abstract: At 12:30 p.m. on April 23, 2018, an employee was getting a cutting torch ready in preparation to cut steel plates connecting catwalks. While on the 35 ft high catwalk, the second tank exploded, resulting in the employee falling to the ground. The employee sustained a broken leg and second degree burns to half of the face.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Manufacturing plant | Demolition | 40 | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1310708.015 | 35 | M | Hospitalized injury | Construction trades, n.e.c. | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Demolition Fatality Cause: |
Translate