Accident Summary Nr: 104498.015 - Employee is electrocuted when boom contacts power line
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1306972.015 | 04/05/2018 | 237130 | Red Stag Contractors, Llc |
Abstract: At 3:15 p.m. on April 4, 2018, an employee was standing by as a coworker operated the boom of a truck. The employee was leaning on the boom truck and the coworker was operating the boom truck in close vicinity of an overhead power line. The boom made contact with the energized line, resulting in the employee being electrocuted. The incident investigation determined that the electrical current had run down the boom and through the employee because he was leaning on the truck.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1306972.015 | 52 | M | Fatality | Telephone line installers and repairers |