Accident Report Detail
Accident Summary Nr: 104348.015 - Employee is killed when caught between the lift arms and the
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1305725.015 | 03/30/2018 | 1081 | 238910 | 317720142 - Advanced Earth Stabilization Llc |
Abstract: At 2:30 p.m. on March 30, 2018, an employee was installing helical piers to secure a foundation on a new construction site. The employee was outside the skid steer (track loader) cab. The equipment was on. A hydraulic hose that operates the skid steer helical pier driver attachment was wrapped around the right joystick of the skid steer causing the lift arms of the skid steer to activate and lower. The employee was caught between the lift arms and the cab of the track loader and is killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1305725.015 | 36 | M | Fatality | Excavating and loading machine operators | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Other Activities-Installing Ornamental And Archite Fatality Cause: |