Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 102199.015 - Employee is doused with chemical and later dies at hospital

Accident Summary Nr: 102199.015 -- Report ID: 1055350 -- Event Date: 12/27/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1285511.01512/28/2017325199Wa317947726 - Moses Lake Industries Inc

Abstract: At 4:45 p.m. on December 27, 2017, an employee was adding piping from a man-lift to a chemical tank when he struck a transducer on a nearby chemical tank containing tetra-methyl ammonium hydroxide. The employee was drenched and was able to lower the man-lift and get into the emergency wash station. The employee was assisted by several coworkers in washing the chemical off and paramedics arrived shortly afterwards, transporting the employee to MLK Hospital. The employee was stabilized and then airlifted to Harborview Hospital where he passed away on January 8, 2018.

Keywords: Chemical, Emergency Response, Pipe

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1285511.015 39 M Fatality Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.