Accident Summary Nr: 101788.015 - Employee is covered in a trench cave-in and is killed

Accident Summary Nr: 101788.015 -- Report ID: 0522000 -- Event Date: 12/28/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1285365.01512/28/2017238910Jk Excavating & Utilities, Inc.

Abstract: At 11:49 a.m. on December 28, 2017, an employee was working inside an 8 foot trench box located in a trench that was 16 feet deep when the trench wall caved-in and trapped the employee inside the box. A coworker removed the trench box and the employee was covered by a second cave-in. The employee was killed from asphyxia.

Keywords: Asphyxiated, Buried, Cave-In, Trench, Trench Box
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition   1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1285365.015 25 M Fatality Plumber, pipefitter and steamfiter apprentices Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.