Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 101610.015 - Employee has two fingers amputated by press brake

Accident Summary Nr: 101610.015 -- Report ID: 0522000 -- Event Date: 12/13/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1283952.01512/19/2017332322Seal Tite Llc

Abstract: At 7:45 a.m. on December 13, 2017, an employee was working for a manufacturer of sheet metal work. He was operating a press brake. While he was operating the press brake, its ram came down upon his fingers. The press brake was not guarded. Further, the press brake malfunctioned, as its double-tripping action, or "ghost trip" function actuated. The employee sustained the amputation of two fingers. He was hospitalized.

Keywords: Amputated, Amputation, Caught In, Equipment Operator, Finger, Machine Guarding, Mech Malfunction, Press Brake, Ram

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1283952.015 56 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.