Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 101023.015 - Employees are burned by fire ball from coal pulverizer

Accident Summary Nr: 101023.015 -- Report ID: 0419400 -- Event Date: 11/17/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1279193.01511/20/2017236210Mcabee Construction, Inc

Abstract: At 12:00 p.m. on November 17, 2017, Employees #1 and #2, employed by a construction company, were installing metal plates under steel I-beams at a multiemployer construction site. A fire ball created by combustible coal dust flew out of a pulverizer and struck the employees. Emergency services were called, and the two employees were transported to the hospital. Employee #2 was treated for skin burns and released. Employee #1 was treated for skin burns and hospitalized.

Keywords: Beam, Burn, Coal, Coal Dust, Combustible Dust, Construction, Fire, Skin, Steel Erection, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1279193.015 24 M Non Hospitalized injury Construction laborers
2 1279193.015 32 M Hospitalized injury Millwrights

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close