Accident Summary Nr: 100622.015 - Employee is crushed and killed by distributor arm in silo

Accident Summary Nr: 100622.015 -- Report ID: 0627700 -- Event Date: 11/02/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1276575.01511/03/2017327215Cardinal Float Glass

Abstract: At 1:00 p.m. on November 2, 2017, an employee was trying to troubleshoot a plumb bob for a silo. The employee went around the interlocked gate into the distributor arm area and the distributor arm moved and eventually struck the back of the employee. He was pinned between the mouth of the arm and the opening of the silo. The employee was crushed and fatally injured.

Keywords: Caught Between, Machine Guarding, Silo

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1276575.015 45 M Fatality Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.