Accident Summary Nr: 1005511 - Employee killed when struck by compactor bucket

Accident Summary Nr: 1005511 -- Report ID: 0253680 -- Event Date: 11/16/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10474167311/18/198849530Tupper Lake Village Landfill

Abstract: On November 16, 1988, Employee #1, a mechanic, and a coworker, an equipment operator, were repairing a John Deere compactor at the village landfill. The bucket of the compactor was in an elevated position, supported by an 11-ft-6-in. metal pipe. The nose of the pipe was resting on wet or damp sand. Employee #1 had replaced the hydraulic lift cylinder and was attempting to position and secure an O-ring to stop an oil leak, but he was unable to stop the leak long enough to secure the gasket. At approximately 1:15 p.m., Employee #1 asked the coworker to get into the cab and start the compactor engine. When the coworker started the engine, the support pipe slipped out almost immediately. Employee #1, who was between the elevated bucket and the machine, was struck by the lift arm as the bucket came down. He was killed instantly.

Keywords: REPAIR, ROLLER--CONST EQUIP, WORK RULES, MECHANIC, SLIP, STRUCK BY, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104741673 Fatality Amputation Heavy equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close